Posted under Web HostingNetwork 1 Location: Liquid Web,
|
|
Two Full OC3c connections through premium bandwidth providers Savvis/Cable & Wireless and Verio |
|
- |
BGP4 (Border Gateway Protocol) employed at the network edge for performance and redundant line reliability |
|
- |
Cisco 7206 VXR border router with NPE-G1 with redundant backup 7206 VXR on standby |
|
- |
Cisco 3550 Catalyst backbone switch with redundant backup on standby |
|
- |
Hewlett-Packard Procurve rack switches |
|
- |
Network VLan segmented by customer type and use |
Robust Electrical System Including:
|
- |
Incoming commercial power service routed underground to a dedicated transformer |
|
- |
300 kVA Powerware 9315 centralized UPS with redundant battery cabinets |
|
- |
Over 4 hours of UPS runtime on battery backup at current load |
|
- |
313 kVA standby Cummins diesel generator (Automatically activated by transfer switch) |
|
- |
Over 24 hours of runtime on generator before requiring additional fuel at full load |
|
- |
Liebert Precision power distribution unit |
|
- |
UPS full maintenance bypass allows for power upgrades and UPS service without interruption of power to equipment |
Security:
|
- |
Complete network IDS (Intrusion Detection System) monitors data and network security transparently through an optical tap |
|
- |
Closed circuit security camera system covering all building and data center entrances along with integrated motion detection systems |
|
- |
Six to eight weeks of security data is retained at all times |
|
- |
Access to facility is restricted to technical staff employees |
Building Structure and Floor Plan:
|
- |
5,500 square feet of available data center space with expansions to over 10,000 square feet soon underway |
|
- |
Industry-standard hard floors covered by vinyl tile and overhead wiring systems for better cooling capability and more secure cable infrastructure |
|
- |
Built to surpass local area building codes and seismic requirements |
Climate Control:
|
- |
Multiple Liebert Precision 22 ton up flow air conditioning units (N+1) |
|
- |
Regulates temperature and humidity precisely for optimal server stability |
|
- |
Air filtration systems remove dust and foreign particulates from circulation |
|
- |
Independent compressors and cooling loops enhance redundancy |
|
- |
Capacity for over 120 Tons of Cooling |
Network 2 Location: The Planet, Dallas, TX, USA.
| - | 60,000 sq. ft. facility |
| - | Simplex security badge entry/exit on all doors to facility |
| - | Multiple TXU electrical grids |
| - | Cisco Certified Network |
Fully meshed and redundant with 9 backbone providers:
| - | AT&T |
| - | Sprint |
| - | Time Warner |
| - | UUNET |
| - | Verio |
| - | Cogent |